# PWR-203 — Prosthetic control: learner worksheet

Release: Revision 7T · Full Tutorial Edition
Estimated time: Estimated 14 min reading; practical time is provider-set
Difficulty: Intermediate
Equipment: Specialist equipment — Declared Prosthetic control fixture: A myoelectric training hand moves an empty foam cup from one marked pad to another on a table. The prosthetist controls fit, thresholds and permissible repetitions.; Setup aid for Inspect fit and skin: Use only the configured device, empty foam object, clear table and approved stop procedure.; Prosthetic control log: Task success, control error, comfort, wear time, abandonment, maintenance and device-on/off daily participation; retain Prosthetic control errors, assistance, stop and fallback.; Prosthetic-control provider sheet: from “Self-Contained Neuromusculoskeletal Arm Prostheses”, record interface, trained actions, device configuration and functional outcome; from the myoelectric robot-assisted training pilot, record participants, training condition, dose owner and measured change. Use the WHO/UNICEF report to keep the user goal, fallback and service support visible. Only the prosthetist sets fit and thresholds.
Space: Specialist setting

Automated structural checklist: 10 of 10 structural checks present
Evidence quality/context: G4; Focused research depth
Automated method-quality band: Comprehensive
Method-rating basis: Structure coverage, instruction/check specificity, alternative distinctness, source troubleshooting, comparison depth and whether purpose/check fields are authored rather than derived.

Editorial review: Pending manual editorial sign off

## Before you begin
- [ ] I read the tutorial authority and stop conditions.
- [ ] I have the required equipment/space or a declared accessible alternative.

## Canonical source context

The rehabilitation team configures a myoelectric hand for one empty-foam-cup transfer, with rest windows, fit checks and a safe open or powered-down default. The learner controls the declared grasp, counts unintended activations and handles one signal fault. Heavier, sharp and everyday objects remain outside the demonstrated capability.

Target outcome: With the rehabilitation team, the learner calibrates rest and active states, completes a provider-selected grasp, counts unintended activations and returns to a safe open or powered-down state.

### Authority and setup conditions

- Obtain rehabilitation-team clearance and the device-specific training plan.
- Use only the configured device, empty foam object, clear table and approved stop procedure.
- Start check for Prosthetic control: Target, load, distance and stop state are exact.
- Top-of-sheet stop for Prosthetic control: Stop for skin redness that persists, wound, swelling, pain, heat, odour, loose hardware or new discomfort.

### Required or supplied materials

- Declared Prosthetic control fixture: A myoelectric training hand moves an empty foam cup from one marked pad to another on a table. The prosthetist controls fit, thresholds and permissible repetitions.
- Setup aid for Inspect fit and skin: Use only the configured device, empty foam object, clear table and approved stop procedure.
- Prosthetic control log: Task success, control error, comfort, wear time, abandonment, maintenance and device-on/off daily participation; retain Prosthetic control errors, assistance, stop and fallback.
- Prosthetic-control provider sheet: from “Self-Contained Neuromusculoskeletal Arm Prostheses”, record interface, trained actions, device configuration and functional outcome; from the myoelectric robot-assisted training pilot, record participants, training condition, dose owner and measured change. Use the WHO/UNICEF report to keep the user goal, fallback and service support visible. Only the prosthetist sets fit and thresholds.

## 1. Choose one functional action

The learner and team define “grasp the empty foam cup, move 20 cm and release on the blue pad,” plus the safe default.

Why: Target, load, distance and stop state are exact.

Success check: Target, load, distance and stop state are exact.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “Target, load, distance and stop state are exact.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 2. Inspect fit and skin

The prosthetist checks socket, electrodes, alignment, skin, comfort and device condition before activation.

Why: No new redness, wound, pressure or loose component is present.

Success check: No new redness, wound, pressure or loose component is present.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “No new redness, wound, pressure or loose component is present.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 3. Record the rest signal

With the limb supported, relax for the provider-set interval while the clinician checks baseline noise and unintended movement.

Why: The device remains in the safe default during rest trials.

Success check: The device remains in the safe default during rest trials.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The device remains in the safe default during rest trials.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 4. Calibrate one active command

Produce the agreed muscle signal while the provider sets and verifies the threshold; do not change settings independently.

Why: The intended open or close command occurs without a second function firing.

Success check: The intended open or close command occurs without a second function firing.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The intended open or close command occurs without a second function firing.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 5. Rehearse without an object

Practise open, approach, close, hold and open at slow speed, returning to default between trials.

Why: The sequence completes three times without unintended activation.

Success check: The sequence completes three times without unintended activation.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The sequence completes three times without unintended activation.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 6. Move the foam cup

Approach inside the marked zone, grasp with provider-approved force, move to the blue pad and fully release.

Why: Cup arrives upright and the hand returns to default.

Success check: Cup arrives upright and the hand returns to default.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “Cup arrives upright and the hand returns to default.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 7. Log error and comfort

Record success, drop, crush, unintended activation, correction, comfort and assistance for every trial.

Why: No error is hidden inside an overall success count.

Success check: No error is hidden inside an overall success count.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “No error is hidden inside an overall success count.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 8. Test fallback and finish

On a staged signal fault, stop, support the device and use the team’s disable or removal procedure; inspect skin again.

Why: The learner demonstrates the stop response and the provider authorises the next step.

Success check: The learner demonstrates the stop response and the provider authorises the next step.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The learner demonstrates the stop response and the provider authorises the next step.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## Reflection

What changed?

________________________________________________________________________________

What remains difficult?

________________________________________________________________________________

What will I repeat, adapt, ask for help with, or stop?

________________________________________________________________________________

---
Completion of this worksheet demonstrates tutorial participation only. It does not establish capability, qualification, safety clearance, diagnosis, treatment or independent validation.