# PWR-020 — Fatigue resistance: learner worksheet

Release: Revision 7T · Full Tutorial Edition
Estimated time: Estimated 11 min reading; practical time is provider-set
Difficulty: Intermediate
Equipment: Specialist equipment — Calibrated handgrip dynamometer with visible target band; Recorded handle position and supported arm posture; Work-rest timer; Force-trace export or session sheet; A handgrip-pulse record for device and handle, side, posture, current baseline, target band, work-rest timing, each pulse, errors, decrement and symptoms.
Space: Specialist setting

Automated structural checklist: 10 of 10 structural checks present
Evidence quality/context: G4; Deep research depth
Automated method-quality band: Comprehensive
Method-rating basis: Structure coverage, instruction/check specificity, alternative distinctness, source troubleshooting, comparison depth and whether purpose/check fields are authored rather than derived.

Editorial review: Pending manual editorial sign off

## Before you begin
- [ ] I read the tutorial authority and stop conditions.
- [ ] I have the required equipment/space or a declared accessible alternative.

## Canonical source context

Fatigue resistance is preservation of a declared task's output and quality across a fixed workload and recovery schedule. This lesson teaches a supervised handgrip-pulse task: establish one submaximal target, squeeze into a visible band for a fixed time, release fully for a fixed interval, repeat the predeclared count and stop when force, timing or grip position fails. The provider controls target, repetitions, work-rest timing and whether fatigue induction is appropriate.

Target outcome: The learner completes a provider-set series of handgrip pulses while valid force, time-in-band, errors and decrement are tracked separately.

### Authority and setup conditions

- Confirm hand, handle setting, arm position, target band, pulse count, work time and rest time.
- Report hand, wrist, elbow, neck or neurological symptoms and recent injury.
- Demonstrate full relaxation to baseline before the next pulse.
- Set the handle, hand, arm and posture from the reference record and watch one complete squeeze-and-release at low force. Begin only when the setup stays still and the hand fully relaxes.
- Use low-force pulses to find the target band and practise full relaxation during the fixed recovery interval before recorded work begins.

### Required or supplied materials

- Calibrated handgrip dynamometer with visible target band
- Recorded handle position and supported arm posture
- Work-rest timer
- Force-trace export or session sheet
- A handgrip-pulse record for device and handle, side, posture, current baseline, target band, work-rest timing, each pulse, errors, decrement and symptoms.

## 1. Set hand and arm

Use the recorded handle position, wrist angle and supported elbow posture; keep the other hand off the device.

Why: Grip leverage changes force and fatigue.

Success check: The setup matches the reference and remains still.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The setup matches the reference and remains still.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 2. Find the target band

Complete one low familiarisation squeeze, raising force smoothly into the band without overshoot.

Why: The task measures controlled repeat output, not an explosive peak.

Success check: The trace enters the band once and stays there.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The trace enters the band once and stays there.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 3. Hold for the fixed time

Keep force inside the band until the hold cue ends while breathing and keeping the wrist still.

Why: Time and force quality must both be preserved.

Success check: The trace stays in band for the required interval.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “The trace stays in band for the required interval.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 4. Release completely

Relax until the trace returns to baseline, then leave the hand open for the full recovery interval.

Why: Partial release adds unmeasured duty and fatigue.

Success check: Every recovery begins at baseline; the visible 'Release completely' check is satisfied.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “Every recovery begins at baseline; the visible 'Release completely' check is satisfied.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 5. Repeat without compensation

Begin the next pulse only on the cue; do not change handle position, brace with the trunk or use the other hand.

Why: Compensation can hide local performance loss.

Success check: Posture and handle remain unchanged; the visible 'Repeat without compensation' check is satisfied.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “Posture and handle remain unchanged; the visible 'Repeat without compensation' check is satisfied.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 6. Stop at the declared failure

End the series when force leaves the band, release is incomplete, timing fails or symptoms reach the stop rule.

Why: The endpoint is preserved task quality, not exhaustion.

Success check: No extra pulse follows the first failure.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “No extra pulse follows the first failure.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## 7. Separate output, errors and decrement

Record force for each pulse, time-in-band, first error and the predeclared decrement. Report symptoms and recovery separately.

Why: Mean output and decrement can move independently.

Success check: Raw pulses remain visible beside the summary.

Accessible alternative: Ask the qualified provider to adapt positioning, cue modality, pace, interface or rest while preserving this step’s declared check: “Raw pulses remain visible beside the summary.” If an adaptation changes the measured task or configuration, record it as a different configuration rather than an equivalent attempt.

Alternative relationship: Conditional equivalence requires target and configuration check

Learner notes:

________________________________________________________________________________

Completed: [ ]

## Reflection

What changed?

________________________________________________________________________________

What remains difficult?

________________________________________________________________________________

What will I repeat, adapt, ask for help with, or stop?

________________________________________________________________________________

---
Completion of this worksheet demonstrates tutorial participation only. It does not establish capability, qualification, safety clearance, diagnosis, treatment or independent validation.
